- 24 -
d) If the oil level is low, add oil to bring the oil level up to the “FULL” mark on
the dipstick. Use oil as specified in the Engine Owner’s Manual.
DO NOT overfill.
IMPORTANT: DO NOT operate the engine with the oil level below the
“LOW” (or “ADD”) mark on the dipstick, or over the “FULL” mark.
5.1.2 Clean engine air cooling system
:
Service Interval: Daily or more often in dry conditions
CAUTION
POTENTIAL HAZARD
Excessive debris can cause the engine and hydraulic
system to overheat.
WHAT CAN HAPPEN
Excessive debris around the engine cooling air intake
and inside of the pump compartment can create a fire
hazard.
HOW TO AVOID THE HAZARD
Clean all debris from around the engine and hydraulic
pumps daily.
a) Stop engine, wait for all moving parts to stop, and remove key.
b) Clean all debris from rotating engine air intake screen and from around
engine shrouding.
5.1.3 Check battery charge
:
Service Interval: Monthly
Allowing batteries to stand for an extended period without recharging them will
result in reduced performance and service life. To preserve optimum battery
performance and life, recharge batteries in storage when the open circuit voltage
drops to 12.4 volts.
Note: To prevent damage due to freezing, battery should be fully charged before
putting away for winter storage.
a) Check the voltage of the battery with a digital voltmeter. Locate the voltage
reading of the battery in the table below and charge the battery for the
recommended time interval to bring the charge up to a full charge of 12.6
volts or greater.
IMPORTANT: Make sure the negative battery cables are disconnected
and the battery charger used for charging the battery has an output of 16
volts and 7 amps or less to avoid damaging the battery (see chart below for
recommended charger settings).
Voltage
Reading
Percent
Charge
Maximum
Charger Settings
Charging Interval
12.6 or greater 100% 16 volts/7 amps No Charging Required
12.4 – 12.6 75 – 100% 16 volts/7 amps 30 Minutes
12.2 – 12.4 50 – 75% 16 volts/7 amps 1 Hour
12.0 – 12.2 25 – 50% 14.4 volts/4 amps 2 Hours
11.7 – 12.0 0 – 25% 14.4 volts/4 amps 3 Hours
11.7 or less 0% 14.4 volts/2 amps 6 Hours or More
5.1.4 Clean grass build-up under deck.
Service Interval: Daily
a) Stop engine, wait for all moving parts to stop, and remove key.